AMAADOR ACADEMYCertificatesVerify a certificate

CMRT

Final check — CMRT Exam Prep: Certified Maintenance and Reliability Technician

Answer the 48 questions. You need 80% or more to pass. You can retry as many times as you like.

Study the course →

Question 1According to the SMRPCO Candidate Handbook, how is the CMRT exam made up?
Question 2Two electricians and a mechanic will work at the same time on one conveyor with a single isolator. How should the isolation be locked?
Question 3You have opened and locked the breaker for a motor and released stored energy. What is the next step before starting work?
Question 4You are the attendant at a tank entry. The entrant collapses inside and does not answer. What should you do?
Question 5In the hierarchy of controls, which measure is normally the most effective?
Question 6Stores has given you a degreaser you have never used for cleaning a gearbox housing. Where do you find its hazards, PPE and spill measures?
Question 7A hydraulic press is electrically locked out, but its ram is stopped in the raised position. What hazard remains?
Question 8The job is finished but a contractor has gone home leaving a personal lock on the isolator. Production wants to start. What happens next?
Question 9A two-leg sling lift is rigged so that each leg makes 30 degrees with the horizontal instead of 60 degrees. What happens to the tension in each leg?
Question 10During a pre-use check you find a chain sling with one stretched link and no identification tag. What should you do?
Question 11A clearance is specified as 0.004 inch. What is it in millimetres?
Question 12Before measuring a shaft, you close your micrometer on its setting standard and it reads 0.01 mm too high. What should you do?
Question 13A spare pump-motor set will stay in stores for many months before use. What does good practice require while it is stored?
Question 14You are closing a work order for a fan bearing change. Which entry best supports future troubleshooting and planning?
Question 15At the end of a gearbox repair you have a pile of oily rags. What is the correct way to deal with them?
Question 16A cover bolt must be torqued to 100 N·m, but your torque wrench is scaled only in lbf·ft. What setting do you use?
Question 17What triggers a predictive (condition-based) maintenance task?
Question 18For a fan bearing, vibration gives about 8 weeks of warning between detectable fault and failure. Which route interval best fits?
Question 19You must take an oil sample from a gearbox for analysis. Which method gives a representative sample?
Question 20A thermography survey of the main switchboards is planned for Sunday, when the plant is shut down. What is the problem with this plan?
Question 21Compressed-air consumption has risen, but the plant is too noisy to hear leaks. Which technique finds them fastest?
Question 22Why is a baseline reading taken on a machine that has just been installed or overhauled and runs well?
Question 23A weekly PM inspection on a gearbox has found nothing in three years, while a nearby pump fails often with no PM at all. What should you do?
Question 24A new colleague on the vibration route places the sensor wherever is easiest to reach on each visit. What is the main problem?
Question 25A technician pumped grease into a motor bearing until it came out of the seal. An hour later the bearing is much hotter than usual. What is the most likely cause?
Question 26What does the grade ISO VG 68 on a gear oil describe?
Question 27Your grease gun is filled with a lithium-complex grease, but the motor's label specifies a polyurea grease. What should you do?
Question 28On your lubrication route, the oil in a gearbox sight glass looks milky. The level is correct. What does this most likely show, and what do you do?
Question 29Before aligning a motor to a pump, you loosen one motor foot and the dial indicator shows it lifts 0.25 mm. What should you do first?
Question 30Which dial-indicator alignment method takes a rim reading on each shaft, with the bracket on the other shaft?
Question 31A hot-oil pump was aligned to zero offset when cold, but vibration is high once it reaches operating temperature. What was most likely missed?
Question 32On a PM check you find a guard interlock switch held closed with tape, so the machine runs with the guard open. What should you do?
Question 33You receive a work order that only says 'pump noisy'. What is the best first step?
Question 34The HMI shows zero flow on a cooling line, yet the pump motor current and discharge pressure are normal and the heat exchanger outlet is cool. What is the most likely fault?
Question 35Which document best shows a unit's process lines, valves, instruments and control loops?
Question 36A fan's vibration jumped the day after its motor was replaced. The fan had run smoothly for years. Where should troubleshooting start?
Question 37A centrifugal pump has low flow, very low suction pressure and a sound like gravel passing through it. What should you check first?
Question 38A conveyor will not start. Its control circuit has twelve emergency-stop contacts wired in series along 300 m. Using the half-split method, where do you measure first?
Question 39The CMMS shows the same gear coupling on a mixer has been replaced three times in six months. What is the right approach now?
Question 40While troubleshooting a temperature loop, a technician changed the controller tuning and replaced the sensor at the same time. The problem disappeared. What is the weakness?
Question 41A bearing removed after only two weeks in service shows evenly spaced dents in the raceway at the same spacing as the balls. What is the most likely cause?
Question 42Bearings on a motor driven by a variable frequency drive keep failing. The races show fine washboard flutes. What should you recommend?
Question 43A new bearing must go on a shaft with an interference fit. Which fitting method is correct?
Question 44You are fitting a new gasket on an eight-bolt pipe flange. How should the bolts be tightened?
Question 45One belt on a four-belt V-belt drive has snapped; the other three are a year old. What is the correct repair?
Question 46One hour after a pump bearing change, the bearing temperature is still climbing steadily with no sign of levelling off. What should you do?
Question 47Spare stud bolts for a high-temperature flange are out of stock. A colleague suggests using ordinary bolts of a different grade from the shelf. What applies?
Question 48A repair on a conveyor drive is complete. What must you confirm before the locks are removed?