السؤال 1Under the MDR, what mainly decides whether a product is a medical device?
السؤال 2Your company imports class IIa devices from a manufacturer in China into the EU. Before placing a shipment on the market, what must the importer check?
السؤال 3A distributor in France decides to repackage a CE-marked device into smaller boxes and sell it under its own brand name. What is the main consequence?
السؤال 4What is the role of a notified body under the MDR?
السؤال 5How does ISO 13485:2016 differ from ISO 9001?
السؤال 6During a test, a technician writes a wrong value on a paper record. What is the correct way to fix it?
السؤال 7Under ISO 13485 clause 4.2.5, what is the minimum retention period for quality records?
السؤال 8A small company only distributes devices and does no design work. In its quality manual it lists design and development as not applicable. When is this acceptable?
السؤال 9A team is classifying a new device. Two Annex VIII rules apply: one gives class IIa, the other class IIb. Which class applies?
السؤال 10Which class I devices still need a notified body under the MDR, for the relevant aspects?
السؤال 11A manufacturer of a class III implant wants to rely on clinical data from a competitor's equivalent device. Under the MDR, what is normally needed?
السؤال 12What does applying a harmonised standard cited in the EU Official Journal give a manufacturer?
السؤال 13Bench tests show a new catheter meets every drawing and specification. Users in a simulated ward still struggle to connect it correctly. What has failed?
السؤال 14A risk analysis finds that a pump's tubing can be loaded backwards, causing free flow. A design change to make wrong loading impossible is feasible. What should the team do first?
السؤال 15Under ISO 14971, risk is the combination of which two elements?
السؤال 16Six months after launch, several complaints describe a battery overheating mode that the risk file never considered. What should happen to the risk management file?
السؤال 17Your sterilisation subcontractor tells you, after the fact, that it moved your products to a different steriliser last month. What is the main concern?
السؤال 18In a UDI, what does the production identifier (UDI-PI) contain?
السؤال 19At goods-in, a storekeeper finds a box of components with a damaged label and no lot number. Production is waiting for them. What should he do?
السؤال 20Under clause 7.4, how much control should a manufacturer apply to a supplier?
السؤال 21A hospital pharmacist mentions on the phone that a syringe barrel cracked during use, but says she does not want to file a complaint. How should the call be handled?
السؤال 22Under MDR Article 87, what is the maximum time to report a serious incident involving a death?
السؤال 23A CAPA for repeated label mix-ups was closed the day new labels were printed. Two months later the same mix-up happens again. What was missing?
السؤال 24How often must a manufacturer update the PSUR for a class IIb device under the MDR?
السؤال 25An internal auditor writes: "Complaint handling is poor and the team seems disorganised." Why is this a weak finding?
السؤال 26Under MDR Annex IX, how often must a notified body carry out unannounced audits of a manufacturer?
السؤال 27You are planning next year's internal audit programme. CAPA had two major findings last year and sterilisation changed supplier. How should this affect the plan?
السؤال 28During a notified body audit, the auditor asks a production operator for the training record for a new machine. The operator is not sure where it is. What is the best answer?