Final check — ISO 13485 and EU MDR Awareness for Medical Devices

Answer the 28 questions. You need 80% or more to pass. You can retry as many times as you like.

Study the course →

Question 1Under the MDR, what mainly decides whether a product is a medical device?
Question 2Your company imports class IIa devices from a manufacturer in China into the EU. Before placing a shipment on the market, what must the importer check?
Question 3A distributor in France decides to repackage a CE-marked device into smaller boxes and sell it under its own brand name. What is the main consequence?
Question 4What is the role of a notified body under the MDR?
Question 5How does ISO 13485:2016 differ from ISO 9001?
Question 6During a test, a technician writes a wrong value on a paper record. What is the correct way to fix it?
Question 7Under ISO 13485 clause 4.2.5, what is the minimum retention period for quality records?
Question 8A small company only distributes devices and does no design work. In its quality manual it lists design and development as not applicable. When is this acceptable?
Question 9A team is classifying a new device. Two Annex VIII rules apply: one gives class IIa, the other class IIb. Which class applies?
Question 10Which class I devices still need a notified body under the MDR, for the relevant aspects?
Question 11A manufacturer of a class III implant wants to rely on clinical data from a competitor's equivalent device. Under the MDR, what is normally needed?
Question 12What does applying a harmonised standard cited in the EU Official Journal give a manufacturer?
Question 13Bench tests show a new catheter meets every drawing and specification. Users in a simulated ward still struggle to connect it correctly. What has failed?
Question 14A risk analysis finds that a pump's tubing can be loaded backwards, causing free flow. A design change to make wrong loading impossible is feasible. What should the team do first?
Question 15Under ISO 14971, risk is the combination of which two elements?
Question 16Six months after launch, several complaints describe a battery overheating mode that the risk file never considered. What should happen to the risk management file?
Question 17Your sterilisation subcontractor tells you, after the fact, that it moved your products to a different steriliser last month. What is the main concern?
Question 18In a UDI, what does the production identifier (UDI-PI) contain?
Question 19At goods-in, a storekeeper finds a box of components with a damaged label and no lot number. Production is waiting for them. What should he do?
Question 20Under clause 7.4, how much control should a manufacturer apply to a supplier?
Question 21A hospital pharmacist mentions on the phone that a syringe barrel cracked during use, but says she does not want to file a complaint. How should the call be handled?
Question 22Under MDR Article 87, what is the maximum time to report a serious incident involving a death?
Question 23A CAPA for repeated label mix-ups was closed the day new labels were printed. Two months later the same mix-up happens again. What was missing?
Question 24How often must a manufacturer update the PSUR for a class IIb device under the MDR?
Question 25An internal auditor writes: "Complaint handling is poor and the team seems disorganised." Why is this a weak finding?
Question 26Under MDR Annex IX, how often must a notified body carry out unannounced audits of a manufacturer?
Question 27You are planning next year's internal audit programme. CAPA had two major findings last year and sterilisation changed supplier. How should this affect the plan?
Question 28During a notified body audit, the auditor asks a production operator for the training record for a new machine. The operator is not sure where it is. What is the best answer?