Final check — ISO 15189:2022 Medical Laboratory Quality Awareness

Answer the 24 questions. You need 80% or more to pass. You can retry as many times as you like.

Study the course →

Question 1Which statement about ISO 15189:2022 is correct?
Question 2A clinic director asks why her laboratory needs ISO 15189 accreditation when the group already holds ISO 9001 certification. What is the best answer?
Question 3In ISO 15189:2022, which clause groups the pre-examination, examination and post-examination requirements?
Question 4A new staff member asks what the main purpose of ISO 15189 is. Which answer best reflects the standard?
Question 5A prescriber who owns shares in your laboratory asks you to remove a ‘haemolysed sample’ comment because it makes his clinic look bad. What should you do?
Question 6A caller says he is a patient’s brother and asks for her HIV result by phone. What is the correct response?
Question 7Under ISO 15189, what must happen before a trained technician validates results alone?
Question 8The reagent fridge log shows 11 °C overnight; the required range is 2 to 8 °C. What should you do first?
Question 9A phlebotomist approaches a sleepy elderly patient. How should she confirm his identity before drawing blood?
Question 10To save time on a morning round, a nurse wants to print and stick labels on all tubes before going to the patients. What is the risk?
Question 11A cerebrospinal fluid sample arrives with the patient’s name but no date of birth, against the two-identifier rule. What is the best course?
Question 12Which item must the laboratory record for each sample at the pre-examination stage?
Question 13A laboratory introduces a CE-marked kit, used exactly as the manufacturer intends. What must it do before patient use?
Question 14A colleague says the laboratory’s EQA samples should be run three times by the most senior scientist to be safe. What is wrong with this?
Question 15IQC for TSH was rejected at 10:00. The cause, a calibration drift, is fixed at 11:00. The last acceptable control was at 07:00. What else must be done?
Question 16For a quantitative test, what does ISO 15189 expect regarding measurement uncertainty?
Question 17A critical sodium of 118 mmol/L is phoned to a ward nurse. What must the technician do during the call?
Question 18A creatinine result released yesterday is found to have come from a mislabelled sample. How should the report be handled?
Question 19A ward manager buys new glucose meters online and starts using them without telling the laboratory. Under Annex A, what is the main problem?
Question 20After an update of the LIS-to-hospital interface, what does ISO 15189 require before relying on it?
Question 21An investigation of repeated delays in urgent troponin results concludes ‘root cause: staff to be retrained’. What is the weakness?
Question 22What distinguishes a correction from a corrective action?
Question 23The quality officer plans the annual internal audit and wants to audit the pre-analytical process she wrote and manages herself. What is the issue?
Question 24Preparing the management review, the director proposes to leave out the rising rate of rejected samples because it ‘looks bad’. What should happen?