AMAADOR ACADEMYالشهاداتالتحقق من شهادة

VAC1

الاختبار النهائي — التحضير لامتحان محلل الاهتزازات الفئة الأولى (ISO 18436‑2)

أجب عن الأسئلة الـ42. تحتاج إلى 80% أو أكثر للنجاح. يمكنك إعادة المحاولة كلما أردت.

هذا الاختبار النهائي متاح بـالإنجليزية.

ادرس الدورة ←

السؤال 1According to the Vibration Institute's analyst categories page, what is the minimum training required before the Category I exam?
السؤال 2A technician has completed a 30-hour course but has collected vibration data for only two months. He wants to sit the Vibration Institute Category I exam next week. What should he be told?
السؤال 3Which standard sets the requirements for bodies that certify persons, such as vibration analyst certification bodies?
السؤال 4On a critical fan, a bearing fault typically becomes detectable by vibration about six weeks before failure. The fan is on a quarterly route. What is the main weakness?
السؤال 5During a route you find a new, clear change on a compressor gearbox. You are certified Category I. Which task is clearly yours under ISO 18436-2?
السؤال 6What triggers maintenance work in a condition-based (predictive) strategy?
السؤال 7A two-pole motor runs at 3600 RPM. What is its running speed in hertz?
السؤال 8On a time waveform, the main repeating cycle lasts 25 ms. If this is 1× running speed, what is the shaft speed?
السؤال 9A pump turns at 1480 RPM. The spectrum shows a strong peak at 148 Hz. What order of running speed is this peak?
السؤال 10A pure sine vibration measures 4.0 mm/s RMS. What is its peak value?
السؤال 11A shaft displacement report gives 80 µm peak-to-peak for a nearly pure 1× signal. A colleague needs the peak value for a calculation. What should you give?
السؤال 12Why does the crest factor of an acceleration signal tend to rise when a rolling bearing starts to impact?
السؤال 13Which measurement parameter best shows early rolling-bearing defects that generate frequencies of several kilohertz?
السؤال 14A bearing housing reads 10 mm/s peak at 50 Hz, almost a pure sine. The customer's limit is in displacement, peak-to-peak. About what value should you report?
السؤال 15A North American report gives 0.2 in/s peak. What is this in mm/s peak?
السؤال 16A pump baseplate has a natural frequency close to running speed. A contractor proposes bolting a heavy steel plate onto it without adding any stiffness. What happens to the natural frequency?
السؤال 17A motor on a steel frame vibrates at 1× far more horizontally than vertically. Changing speed by 3 % halves the amplitude. Balancing last month made little lasting difference. What should you suspect and report?
السؤال 18What is 1 g of acceleration in SI units?
السؤال 19Which accelerometer mounting method gives the widest usable frequency range?
السؤال 20Your collector shows the accelerometer bias voltage at almost zero and the overall value near zero on a running pump. What is the most likely cause?
السؤال 21Two colleagues share a route. One places the magnet on the painted mark; the other places it wherever is convenient on the housing. The trend for that point jumps up and down each month. What is the best fix?
السؤال 22What does a permanently installed proximity (eddy-current) probe measure on a machine with sleeve bearings?
السؤال 23The only flat spot near a motor bearing is a painted, slightly flaking surface; bare flat metal is available on the bearing cap 3 cm away. Where should the magnet go?
السؤال 24A route point on a conveyor drive can only be reached by putting your arm past a fixed guard close to the coupling. What should you do?
السؤال 25A spectrum is set to Fmax 2000 Hz with 800 lines. What is the frequency resolution?
السؤال 26With Fmax 500 Hz and 400 lines, two peaks 1 Hz apart appear as one broad peak. The analyst needs them separated. Which change helps most?
السؤال 27How long does one average take with 1600 lines and Fmax 400 Hz?
السؤال 28On a hammer mill bearing, the time waveform shows peaks that are cut flat at the same level in both directions. What does this most likely indicate?
السؤال 29After a new extension cable was laid alongside a power cable, every machine on the route shows a sharp peak at exactly 50 Hz, even a 300 RPM agitator. What is the most likely cause?
السؤال 30Which window is normally used for routine route spectra on running machines?
السؤال 31A fan shows high 1× in both horizontal and vertical directions, low axial vibration, a clean sinusoidal waveform and little else in the spectrum. Which condition is most likely?
السؤال 32On a motor at 1490 RPM, the acceleration spectrum shows a peak at 3.58× running speed with harmonics, rising over three months. What should you flag?
السؤال 33On a 50 Hz plant, a motor shows a strong peak at 100 Hz. When the analyst cuts the power with the collector running, the 100 Hz peak vanishes immediately while 1× decays as the rotor slows. What does this suggest?
السؤال 34In ISO 20816-1, what does evaluation zone B mean?
السؤال 35Pump A has been steady at the upper part of zone C for a year with a known, accepted cause. Pump B is still in zone B but its overall level has doubled in one month. What should your route report highlight?
السؤال 36A pump bearing shows a long series of 1× harmonics up to 10×, some half-order peaks and a raised noise floor, much worse vertically. What should you suspect?
السؤال 37What is the synchronous speed of a 2-pole AC motor on a 60 Hz supply?
السؤال 38A centrifugal pump with a 5-vane impeller runs at 1780 RPM. At what frequency should you expect the vane pass peak?
السؤال 39A gearbox input pinion has 30 teeth and turns at 1500 RPM. What gear mesh frequency should appear in the spectrum?
السؤال 40A motor at 1480 RPM drives a fan through belts. The motor pulley is 200 mm and the fan pulley is 400 mm. What 1× frequency should you look for on the fan bearings?
السؤال 41Misalignment has been confirmed on a motor-pump set. One motor foot rocks when its bolt is loosened. What should the mechanics do first?
السؤال 42An extraction fan was cleaned and balanced this morning after high 1× readings. What is the right next step for the vibration programme?