AMAADOR ACADEMYCertificatesVerify a certificate

VAC1

Final check — Vibration Analyst Category I (ISO 18436-2) Exam Prep

Answer the 42 questions. You need 80% or more to pass. You can retry as many times as you like.

Study the course →

Question 1According to the Vibration Institute's analyst categories page, what is the minimum training required before the Category I exam?
Question 2A technician has completed a 30-hour course but has collected vibration data for only two months. He wants to sit the Vibration Institute Category I exam next week. What should he be told?
Question 3Which standard sets the requirements for bodies that certify persons, such as vibration analyst certification bodies?
Question 4On a critical fan, a bearing fault typically becomes detectable by vibration about six weeks before failure. The fan is on a quarterly route. What is the main weakness?
Question 5During a route you find a new, clear change on a compressor gearbox. You are certified Category I. Which task is clearly yours under ISO 18436-2?
Question 6What triggers maintenance work in a condition-based (predictive) strategy?
Question 7A two-pole motor runs at 3600 RPM. What is its running speed in hertz?
Question 8On a time waveform, the main repeating cycle lasts 25 ms. If this is 1× running speed, what is the shaft speed?
Question 9A pump turns at 1480 RPM. The spectrum shows a strong peak at 148 Hz. What order of running speed is this peak?
Question 10A pure sine vibration measures 4.0 mm/s RMS. What is its peak value?
Question 11A shaft displacement report gives 80 µm peak-to-peak for a nearly pure 1× signal. A colleague needs the peak value for a calculation. What should you give?
Question 12Why does the crest factor of an acceleration signal tend to rise when a rolling bearing starts to impact?
Question 13Which measurement parameter best shows early rolling-bearing defects that generate frequencies of several kilohertz?
Question 14A bearing housing reads 10 mm/s peak at 50 Hz, almost a pure sine. The customer's limit is in displacement, peak-to-peak. About what value should you report?
Question 15A North American report gives 0.2 in/s peak. What is this in mm/s peak?
Question 16A pump baseplate has a natural frequency close to running speed. A contractor proposes bolting a heavy steel plate onto it without adding any stiffness. What happens to the natural frequency?
Question 17A motor on a steel frame vibrates at 1× far more horizontally than vertically. Changing speed by 3 % halves the amplitude. Balancing last month made little lasting difference. What should you suspect and report?
Question 18What is 1 g of acceleration in SI units?
Question 19Which accelerometer mounting method gives the widest usable frequency range?
Question 20Your collector shows the accelerometer bias voltage at almost zero and the overall value near zero on a running pump. What is the most likely cause?
Question 21Two colleagues share a route. One places the magnet on the painted mark; the other places it wherever is convenient on the housing. The trend for that point jumps up and down each month. What is the best fix?
Question 22What does a permanently installed proximity (eddy-current) probe measure on a machine with sleeve bearings?
Question 23The only flat spot near a motor bearing is a painted, slightly flaking surface; bare flat metal is available on the bearing cap 3 cm away. Where should the magnet go?
Question 24A route point on a conveyor drive can only be reached by putting your arm past a fixed guard close to the coupling. What should you do?
Question 25A spectrum is set to Fmax 2000 Hz with 800 lines. What is the frequency resolution?
Question 26With Fmax 500 Hz and 400 lines, two peaks 1 Hz apart appear as one broad peak. The analyst needs them separated. Which change helps most?
Question 27How long does one average take with 1600 lines and Fmax 400 Hz?
Question 28On a hammer mill bearing, the time waveform shows peaks that are cut flat at the same level in both directions. What does this most likely indicate?
Question 29After a new extension cable was laid alongside a power cable, every machine on the route shows a sharp peak at exactly 50 Hz, even a 300 RPM agitator. What is the most likely cause?
Question 30Which window is normally used for routine route spectra on running machines?
Question 31A fan shows high 1× in both horizontal and vertical directions, low axial vibration, a clean sinusoidal waveform and little else in the spectrum. Which condition is most likely?
Question 32On a motor at 1490 RPM, the acceleration spectrum shows a peak at 3.58× running speed with harmonics, rising over three months. What should you flag?
Question 33On a 50 Hz plant, a motor shows a strong peak at 100 Hz. When the analyst cuts the power with the collector running, the 100 Hz peak vanishes immediately while 1× decays as the rotor slows. What does this suggest?
Question 34In ISO 20816-1, what does evaluation zone B mean?
Question 35Pump A has been steady at the upper part of zone C for a year with a known, accepted cause. Pump B is still in zone B but its overall level has doubled in one month. What should your route report highlight?
Question 36A pump bearing shows a long series of 1× harmonics up to 10×, some half-order peaks and a raised noise floor, much worse vertically. What should you suspect?
Question 37What is the synchronous speed of a 2-pole AC motor on a 60 Hz supply?
Question 38A centrifugal pump with a 5-vane impeller runs at 1780 RPM. At what frequency should you expect the vane pass peak?
Question 39A gearbox input pinion has 30 teeth and turns at 1500 RPM. What gear mesh frequency should appear in the spectrum?
Question 40A motor at 1480 RPM drives a fan through belts. The motor pulley is 200 mm and the fan pulley is 400 mm. What 1× frequency should you look for on the fan bearings?
Question 41Misalignment has been confirmed on a motor-pump set. One motor foot rocks when its bolt is loosened. What should the mechanics do first?
Question 42An extraction fan was cleaned and balanced this morning after high 1× readings. What is the right next step for the vibration programme?