⚡ Certified Energy Manager (CEM) — Exam-Prep
Independent, free exam-preparation covering the public CEM body-of-knowledge domains — study, self-test, then sit an 18-question mock exam.
Certified Energy Manager (CEM) — Exam-Prep is a free, self-paced online course from AMAADOR Academy. Independent, free exam-preparation covering the public CEM body-of-knowledge domains — study, self-test, then sit an 18-question mock exam. It is independent exam-prep built from the syllabus published on this page. An optional verifiable certificate costs $29.
Last updated: June 2026
Independent, free exam-preparation that walks through the publicly published CEM body-of-knowledge domains — energy management & accounting (ISO 50001), electrical and thermal systems, HVAC, building envelope & lighting, measurement & verification (IPMVP), energy economics and rate structures, renewables, demand response and codes, plus combined heat & power and decarbonisation. This is awareness/study material only: it is NOT the official AEE course and is NOT affiliated with or endorsed by the awarding body. It maps to AEE Certified Energy Manager body of knowledge. The course is organized into 10 modules, ending with a final exam (pass mark 70%). It is independent, free exam-preparation training — not an official or accredited review course.
What you'll learn
- Energy management & accounting (ISO 50001)
- Electrical systems & efficiency
- HVAC systems & controls
- Building envelope & lighting
- Thermal systems & waste-heat recovery
- Combined heat & power (CHP) & cogeneration
- Measurement & verification (IPMVP)
- Energy economics & rate structures
- Renewables, demand response & codes
- Carbon accounting & decarbonisation
Learning objectives
- Recognise that this is independent CEM exam-prep across the public syllabus domains, not official AEE courseware
- Build an ISO 50001 energy-management system with a policy, energy review, baseline, SEUs and normalised EnPIs
- Improve electrical efficiency through demand management, power factor, transformers, motors and VFDs
- Analyse HVAC loads, chillers, economizers and controls, and tighten the building envelope and lighting
- Recover thermal energy from boilers, steam systems and waste heat, and evaluate combined heat & power
- Apply IPMVP Options A–D to measure and verify real, defensible energy savings
- Evaluate projects with simple payback, life-cycle cost, NPV and IRR against utility rate structures
- Use solar PV, storage, demand response, ASHRAE 90.1 and carbon accounting to cut peak demand, energy and emissions
Frequently asked questions
What is the Certified Energy Manager (CEM) — Exam-Prep course?
Certified Energy Manager (CEM) — Exam-Prep is a free, self-paced online course from AMAADOR Academy. Independent, free exam-preparation covering the public CEM body-of-knowledge domains — study, self-test, then sit an 18-question mock exam.
Who is the Certified Energy Manager (CEM) — Exam-Prep course for?
It is independent exam-prep for learners working through the syllabus published on this page.
Is this course free, and how is it delivered?
Yes. The course is free, self-paced and online. You can work through the lessons at your own pace. An optional verifiable certificate costs $29.
Is this the official Certified Energy Manager (CEM) — Exam-Prep course or exam?
It is independent, free exam-preparation training — not an official or accredited review course.
How do I get a certificate?
After you complete the course and pass the final exam (pass mark 70%), you can order an optional verifiable certificate of completion for $29.
Course facts
- Estimated study time
- about 3 hours
- Final assessment
- 130 questions · Pass mark 70%
- Available in
- English, Français
- Price
- Free. Optional verifiable certificate: $15
- Last updated
- Published by
- AMAADOR ACADEMY
Course content
1. Energy Management Principles & the ISO 50001 EnMS
The Certified Energy Manager begins with a single mental model: energy is a controllable cost, not a fixed overhead. A structured Energy Management System (EnMS) replaces ad-hoc projects with a permanent, self-correcting business process. This chapter covers the principles, the ISO 50001:2018 standard, and the metrics the exam tests most.
1. Why an EnMS — the business case
Energy is often 1 of the top 3 controllable operating costs in industry and commercial buildings. Studies of certified organizations show typical savings of 5–15% within the first 18 months, much of it from low/no-cost operational and behavioral measures rather than capital projects. The CEM frames every decision around total cost of ownership and persistence of savings — a measure that decays is a measure that failed.
Standard — ISO 50001:2018. The international EnMS standard, structured on the High-Level Structure (Annex SL) shared with ISO 9001 and ISO 14001. Built on Plan-Do-Check-Act (PDCA) and the explicit goal of continual improvement of energy performance — not merely the system. Certification is voluntary and granted by accredited third parties.
2. Energy Accounting, Auditing & Measurement and Verification (IPMVP)
This chapter covers the analytical backbone of the CEM exam: how to account for energy use, how to audit a facility at defined levels of rigor, and how to verify savings credibly using the International Performance Measurement and Verification Protocol (IPMVP). Expect numeric questions on baseline normalization, audit levels, and choosing the correct IPMVP Option.
Energy Accounting & Benchmarking
Energy accounting tracks consumption, cost, and intensity over time so deviations are caught early. The core normalized metric is Energy Use Intensity (EUI) = annual energy ÷ floor area (kBtu/ft²·yr or kWh/m²·yr). Always convert all fuels to a common basis. Remember the source-vs-site distinction: site energy is what the meter reads; source (primary) energy adds generation and delivery losses — grid electricity carries a source factor of roughly 2.8–3.0×, which is why electricity-heavy buildings look worse on a source basis.
Cooling/Heating Degree Days (normalization): CDD = Σ max(0, T_avg − T_base); typical T_base = 65°F (18.3°C). Weather-normalize by regressing energy against HDD/CDD so savings aren't confused with a mild winter.
Tracking Performance: CUSUM
3. Thermal Systems: Boilers, Steam, Furnaces & Heat Recovery
Thermal energy is where a CEM finds the largest, fastest savings in most industrial and commercial plants. Combustion equipment, steam distribution, and waste-heat streams are governed by clear physics and predictable losses. The exam rewards candidates who can quantify those losses, calculate efficiency, and recommend the right recovery measure — so master the numbers, not just the concepts.
Boiler efficiency and combustion fundamentals
A boiler's job is to transfer the chemical energy in fuel to water or steam. Combustion efficiency accounts only for stack (flue gas) losses; thermal (fuel-to-steam) efficiency also includes radiation, convection, and blowdown losses. The two main controllable stack losses are excess air and flue-gas temperature.
Core relationships
- Combustion efficiency ≈ 100% − stack loss
- Stack loss rises with both excess O₂ and net stack temperature (Tstack − Tcombustion air)
- Rule of thumb: each 10–15% reduction in excess air ≈ 1% fuel savings; each 40°F (22°C) drop in stack temperature ≈ ~1% efficiency gain
- Target excess air for natural gas: ~5–10% (≈1–2% O₂); oil/coal need more
4. HVAC Systems & Building Energy
HVAC typically consumes 40–60% of commercial building energy, so the CEM exam weights this domain heavily. You must reason about psychrometrics, system types, control strategies, and the heat-transfer physics of the building envelope — then convert that into kWh and dollars. This chapter builds the working knowledge an energy manager needs to find and quantify HVAC savings.
The Building Load and Psychrometrics
Cooling and heating loads split into sensible (dry-bulb temperature change) and latent (moisture/humidity) components. The sensible-heat equation is the workhorse:
Sensible cooling: Qs (BTU/h) = 1.08 × CFM × ΔT | Latent: QL = 0.68 × CFM × ΔW(gr/lb) | Total: Qt = 4.5 × CFM × Δh(BTU/lb)
The constants assume standard air density; at altitude they shrink. The psychrometric chart ties dry-bulb, wet-bulb, dewpoint, relative humidity, enthalpy, and humidity ratio together — expect a chart-reading question. One refrigeration ton = 12,000 BTU/h; a rule of thumb for chillers is 0.5–0.6 kW/ton for an efficient water-cooled plant, up to 1.0+ kW/ton for older air-cooled units.
5. Compressed Air, Fans, Pumps & Motor Systems
Motor-driven systems consume roughly 60–70% of all industrial electricity, and the four big rotating loads — motors, pumps, fans, and compressed air — are where the CEM exam concentrates its mechanical-systems questions. The unifying idea is the system curve: efficiency lives not in any single component but in matching equipment to the actual load. Expect numerical questions on affinity laws, compressed-air leak costs, and motor part-load efficiency.
The Affinity Laws (memorize cold)
For centrifugal pumps and fans at varying speed N:
- Flow ∝ N (Q₂/Q₁ = N₂/N₁)
- Pressure/Head ∝ N²
- Power ∝ N³
Worked example: Reduce fan speed from 100% to 80%. Power = 0.80³ = 0.512 → ~49% energy saved while still delivering 80% of the flow. This cubic relationship is why variable-speed drives (VSDs/VFDs) crush throttling, dampers, and bypass valves.
Motor systems
NEMA Premium / IE3 efficiency motors are the baseline; standard-efficiency motors waste 2–8 points. Key exam facts: motor efficiency peaks around 75–100% load and falls off sharply below ~40% load, while power factor degrades even faster at light load. Oversizing is the classic field error — a motor running at 30% load is both inefficient and a poor power factor.
6. Lighting Systems & Controls
Lighting is typically 15–40% of commercial electric use and the fastest-payback retrofit a CEM will see. The exam tests three layers: the source (lamp efficacy), the fixture/space (how efficiently lumens reach the task), and controls (only lighting what is occupied, only as bright as needed). The master metric is luminous efficacy in lumens per watt (lm/W) — and the system limit is Lighting Power Density (LPD), watts of connected lighting per unit area.
Source efficacy — know the numbers
LEDs have displaced legacy sources, but the CEM still expects you to rank technologies and recognise that efficacy quoted is often source lm/W, not luminaire lm/W (the latter accounts for driver, optical and thermal losses).
| Source | Typical efficacy (lm/W) | Rated life (h) |
|---|---|---|
| Incandescent | 10–17 | 1,000 |
| Halogen | 15–22 | 2,000–4,000 |
| CFL | 50–70 | 10,000 |
| T8 / T5 fluorescent | 80–100 | 20,000–30,000 |
| Metal halide (HID) | 65–115 | 10,000–20,000 |
| High-pressure sodium | 90–130 | 24,000 |
| LED (luminaire) | 120–180+ | 50,000–100,000 |
EXAM TRAP High-pressure sodium has high efficacy but a CRI near 20 and orange light — never recommend it where colour rendering matters. LED wins on efficacy, CRI, dimmability, instant restrike and life, so it is the default answer for nearly every retrofit.
7. Electrical Systems, Power Factor & Demand Management
For the CEM, the electrical-systems domain rewards candidates who can move fluently between the power triangle, the structure of a utility bill, and the economics of correction. Expect numerical problems on power factor, demand, load factor, and transformer/conductor losses. This chapter builds that fluency.
The power triangle: kW, kVAR, kVA
AC loads draw two kinds of power. Real power (kW) does useful work and turns the energy meter. Reactive power (kVAR) magnetizes inductive loads (motors, transformers, ballasts) and does no work, but still loads the system. Their vector sum is apparent power (kVA).
Core relationships
- kVA = √(kW² + kVAR²)
- Power Factor (PF) = kW ÷ kVA = cos θ
- kVAR = kW × tan θ
- 3-phase: kVA = (√3 × VLL × I) ÷ 1000
PF ranges 0 to 1. A motor at 0.80 PF means only 80% of the apparent power does work; the rest circulates as reactive current, heating conductors and consuming transformer capacity.
Why low power factor costs money
At fixed kW, lower PF raises the current: I ∝ 1/PF. Higher current means I²R losses rise with the square of the inverse PF, plus you pay PF penalties and use up transformer/feeder capacity you've already bought.
8. Renewable Energy & On-Site Generation: Solar, CHP and Distributed Resources
On-site generation lets the energy manager produce power and heat behind the meter, hedging against rising rates, demand charges, and outages. The CEM exam tests whether you can size a system, evaluate its economics, and understand where each technology fits. This chapter covers solar PV, combined heat and power (CHP), wind, geothermal, and the analysis tools you must master.
Solar Photovoltaics (PV)
PV converts sunlight to DC electricity via the photovoltaic effect, then an inverter produces AC. Key terms: a panel's STC rating (Standard Test Conditions: 1000 W/m², 25 °C cell, AM 1.5) gives nameplate watts; real output is lower due to temperature, soiling, and wiring losses.
Annual PV energy (kWh) = Array kWDC × Peak Sun Hours/day × 365 × Derate factor. A typical derate (PR, performance ratio) is 0.75–0.80.
Worked example: A 100 kWDC array in a 5.0 peak-sun-hour location with PR = 0.78 → 100 × 5.0 × 365 × 0.78 ≈ 142,000 kWh/yr. At $0.12/kWh that offsets ~$17,000/yr.
Combined Heat and Power (CHP / Cogeneration)
9. Energy Economics, Financing & Project Evaluation
The CEM exam tests whether you can defend an energy project in financial language a CFO respects. Engineering savings mean nothing until they survive a capital-budgeting screen. This chapter covers the time value of money, the core economic metrics, life-cycle costing, financing structures, and the traps that catch candidates under exam pressure.
The Time Value of Money
A dollar today is worth more than a dollar next year because it can earn a return. Every advanced metric is built on this. Memorize the single-payment factors — they appear constantly:
Core factors (i = discount rate, n = years)
- Future Worth: F = P(1+i)n (SPCAF)
- Present Worth: P = F / (1+i)n (SPPWF)
- Uniform series PW: P = A × [(1+i)n−1] / [i(1+i)n]
- Capital recovery: A = P × [i(1+i)n] / [(1+i)n−1] (CRF)
The Five Metrics You Must Master
| Metric | What it answers | Decision rule |
|---|---|---|
| Simple Payback (SPP) | Years to recover cost | Shorter = better; ignores TVM & tail savings |
| Net Present Value (NPV) | Net wealth created today | Accept if NPV > 0 |
| Internal Rate of Return (IRR) | Discount rate where NPV = 0 | Accept if IRR > hurdle rate (MARR) |
| Benefit-Cost Ratio (SIR) | PW benefits ÷ PW costs | Accept if SIR > 1.0 |
| Life-Cycle Cost (LCC) | Total owning + operating cost | Choose lowest LCC |
10. Energy Procurement, Rate Structures & Carbon/Sustainability
The final domain turns the energy manager into a buyer and a steward. You decide where energy comes from, how it is priced, and what carbon it carries. Mastering this means reading a tariff sheet, structuring a supply contract, and accounting for emissions in a way an auditor would accept.
How a commodity bill is built
In deregulated (restructured) markets the bill splits into two parts: the commodity (energy + capacity, set by your supplier or the wholesale market) and delivery (transmission, distribution, taxes, riders — always billed by the regulated utility). You can shop the commodity; you cannot shop delivery. In a regulated/vertically-integrated market the utility supplies both at a tariff approved by the regulator.
KEY TERMS kW = instantaneous demand (the rate of use); kWh = energy consumed over time. Demand charges bill the peak kW in the period; energy charges bill total kWh. Confusing these is the single most common exam trap.
Procurement product types
Fit-for-purpose buying
- Fixed price — budget certainty, premium for risk transfer
- Index/spot — lowest expected cost, full price volatility
- Block-and-index — hedge a base load, float the rest
- Lock when forward curves are favourable; ladder contract start dates